MBtek
APOLLO Floor Fan Coil FCU

1 / 7

Fan Coil Unit — Floor

APOLLO Floor Fan Coil FCU

Low-profile hydronic heating and cooling for floor-standing, under-window, or low-wall installation.

Size
1.5 Ton (est. 450-675 ft²)
Pipe Configuration
2-Pipe
$861
$60330% OFF

Shipping$146Free

Save 30%
  • Free shipping
  • Secure checkout

Installed in real homes and workshops

Customer Success Stories

I installed the Apollo wall fan coil in our living room and I couldn't be happier. It's incredibly quiet—you barely notice it's running—yet it heats the space up super fast. Plus, the clean white design looks great on the wall.

Whisper-Quiet Comfort

A sleek, modern design that blends perfectly into any room.

Product details

  • Low-profile placement
  • Floor or wall installation
  • Two capacity sizes
  • Flexible controls

USA flag Simply the best floor-mounted fan coil on the market.
Designed in the USA.

APOLLO Vertical Floor Fan Coil Unit

The APOLLO Vertical Floor Fan Coil Unit is a floor-mounted FCU designed for efficient hydronic heating and cooling. Its vertical cabinet design makes it a practical solution for spaces where wall, ceiling, or concealed installation is not ideal.

Built for use with air-to-water heat pumps, boilers, and chilled water systems, this vertical fan coil unit delivers quiet comfort, flexible controls, and reliable performance for residential and light commercial applications.

Key Benefits

  • Vertical floor-mounted design for clean installation where wall or ceiling mounting is not preferred
  • Hydronic heating and cooling for use with heat pumps, boilers, and chilled water systems
  • Quiet operation for comfortable residential and light commercial environments
  • 3-speed high-efficiency fan with 0-10VDC control for precise airflow management
  • Simple 2-pipe or 4-pipe installation for straightforward system integration
  • Built-in drain system for effective condensate management during cooling operation
  • Durable galvanized steel frame with water-resistant construction for long-term reliability
  • Washable air filter for easier maintenance and cleaner indoor air

Thermostat and remote control not included. Requires a compatible FCU thermostat.

Cooling
9,000 BTU (1.5T) / 18,000 BTU (3T)
Heating
13,500 BTU (1.5T) / 27,000 BTU (3T)
Coverage
450–675 ft² (1.5T) / 900–1,350 ft² (3T)
Airflow
300 CFM (1.5T) / 600 CFM (3T)
Noise
30–45 dB (1.5T) / 35–50 dB (3T)
Weight
33.2 lb (1.5T) / 45.4 lb (3T)
Dimensions
35½ × 21⅝ × 7 1/16 in (1.5T) / 49 9/32 × 21⅝ × 7 1/16 in (3T)
Connections
½ in NPT
Control
24VAC or 0–10VDC
Pressure rating
200 PSI

Answers

Frequently asked questions

What size floor fan coil unit do I need?

Estimated coverage guidance is 450–675 ft² for 1.5 Ton and 900–1,350 ft² for 3 Ton. Actual sizing depends on insulation, layout, climate, water temperature, and heat loss.

What are the heating and cooling capacities of the Apollo Vertical Floor Fan Coil Unit?

The 1.5 Ton model delivers 9,000 BTU cooling and 13,500 BTU heating at 300 CFM. The 3 Ton model delivers 18,000 BTU cooling and 27,000 BTU heating at 600 CFM. Actual output depends on entering water temperature and fan speed.

Can the Apollo Vertical Floor Fan Coil Unit be installed on the floor or mounted on a wall?

Yes. It includes floor support legs and can also mount to a wall using a separate support. Anchors, bolts, and nuts are not included.

Is the Apollo Vertical Floor Fan Coil Unit compatible with an air-to-water heat pump?

Yes. It connects to hot or chilled water from an air-to-water heat pump, boiler, or chiller through ½ in NPT fittings. Multiple units can share a common manifold or zone controller.

What thermostat works with the Apollo Vertical Floor Fan Coil Unit?

Remote control and thermostat are not included. Use a compatible 24VAC or 0–10VDC FCU thermostat. Each floor fan coil needs its own dedicated thermostat; multiple units cannot share one.

How quiet is the Apollo Vertical Floor Fan Coil Unit?

The 1.5 Ton model operates at 30–45 dB and the 3 Ton model at 35–50 dB, depending on fan speed.

Does the floor mounted fan coil unit use a 2-pipe or 4-pipe system?

Selectable 2-pipe and 4-pipe variants are available. Two-pipe systems share one hot-or-chilled loop; four-pipe systems use separate hot and chilled circuits.

What are the water connection and pressure requirements?

The unit uses ½ in NPT supply and return connections and is rated to 200 PSI. For cooling, insulate water inlet, outlet, and condensate piping to prevent surface condensation.

How does a vertical floor fan coil compare to wall-mounted or ceiling cassette FCUs?

Its upright cabinet sits low along a wall or floor line, making it useful under windows. Wall FCUs mount higher and are usually fastest to retrofit; ceiling cassettes mount flush and distribute air in multiple directions.

What is included with the Apollo Vertical Floor Fan Coil Unit, and what else will I need?

Each unit includes a washable filter and built-in condensate drain system. A compatible thermostat, supply and return piping, shut-off valves, and cooling-pipe insulation are separate.

MBTEK Google Reviews

Verified Google reviews from MBTEK customers across our heating and hydronic product lines.

Loading reviews…

Installation help and contact

Need an installer?We made it easy for you.

Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.

Any questions?Reach out to us.

Our team can help with product questions, sizing guidance, and next steps.