Need an installer?We made it easy for you.
Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.

1 / 10
Fan Coil Unit — Concealed
Hidden above-ceiling hydronic heating and cooling through short local duct runs or an outlet plenum.
Shipping$148Free
Need help choosing?
Installed in real homes and workshops
I installed the Apollo wall fan coil in our living room and I couldn't be happier. It's incredibly quiet—you barely notice it's running—yet it heats the space up super fast. Plus, the clean white design looks great on the wall.
Whisper-Quiet Comfort
A sleek, modern design that blends perfectly into any room.
The APOLLO Horizontal Concealed Hydronic Fan Coil Unit is designed for hidden ceiling installation, delivering quiet and efficient hydronic heating and cooling with clean, discreet integration. Available in 1.5 Ton, 3.5 Ton, and 6 Ton capacities, it is ideal for residential, condo, office, and light commercial HVAC applications.
Thermostat and remote control not included. Requires a compatible FCU thermostat.
| Coverage | 400–900 / 1,000–1,700 / 1,700–2,800 ft² |
|---|---|
| Cooling | 11–37 KBTU |
| Heating | 18–60 KBTU |
| Airflow | 320–1,260 CFM |
| Power input | 16.7–155.5 W |
| Noise | 18–51 dB(A) |
| Water flow | 2.62–8.15 GPM |
| Weight | 26.7–56.2 lb |
| Installation | Horizontal concealed ceiling |
| Control | 24VAC FCU thermostat |
| Construction | Galvanized steel housing, copper-aluminum coil |
Complete the system

APOLLO Heat Pump
Fan coils need hot or chilled water to run. Our Apollo air-to-water heat pumps supply that water — heating in winter, cooling in summer.
View details
APOLLO Wi-Fi Thermostat
A dedicated fan coil thermostat runs the unit on a schedule and only when there is real demand, reducing energy use and improving room-by-room comfort.
View details
Multi-zone install
The Y-connector lets two fan coil units share a single heat pump circuit, expanding whole-home coverage without adding a second outdoor unit.
View detailsComplete the system

Hydro Station
Combines pump, controls, and electric backup into one compact wall station — less loose parts, faster install, cleaner mechanical room.
View details
Water Heater Tank
The combined buffer and indirect tank lets the heat pump supply household hot water with no separate water heater needed.
View details
Manifold Station
Distributes warm water evenly to each radiant floor loop. Fan coils and radiant can both run from a single outdoor unit.
View detailsAnswers
The APOLLO Concealed FCU is a hidden fan coil installed above a ceiling or soffit. It uses a fan and hydronic coil to heat or cool room air, connecting to hot or chilled water from a heat pump, boiler, or chiller.
It pulls return air from the room, moves it across a hot-water or chilled-water coil, then sends conditioned air through a short duct or outlet plenum. Water temperature, water flow, and fan speed determine output.
Estimated coverage guidance is 400–900 ft² for 1.5 Ton, 1,000–1,700 ft² for 3.5 Ton, and 1,700–2,800 ft² for 6 Ton. Actual sizing depends on insulation, layout, climate, ceiling height, duct design, water temperature, and heat loss.
Yes. It is intended for horizontal above-ceiling or soffit installation. Plan service access so filters, piping, wiring, and condensate components remain reachable.
Yes. Selectable 2-pipe and 4-pipe variants connect to hydronic air-to-water heat pumps. Two-pipe systems share one hot-or-chilled loop; four-pipe systems use separate hot and chilled circuits.
Both. Hot water provides heating and chilled water provides cooling. Performance depends on entering water temperature, water flow, controls, and hydronic design.
A concealed FCU hides equipment and uses short ducting or grilles. A wall FCU is usually fastest to retrofit, a floor FCU sits low on a wall or floor, and a ceiling cassette mounts in the ceiling and distributes air in multiple directions.
Yes. Most installations use short supply and return ducting or an outlet plenum. This is local zone distribution, not whole-house ductwork.
It supports standard 24VAC FCU thermostats. Thermostat and wiring must match selected model, fan-speed setup, and hydronic layout; confirm requirements before wiring.
Plan ceiling space, service access, condensate drainage, supply and return piping, cooling-pipe insulation, electrical and control wiring, air outlet and return layout, and maintenance clearance.
Verified Google reviews from MBTEK customers across our heating and hydronic product lines.
Loading reviews…
Need an installer?We made it easy for you.
Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.
Any questions?Reach out to us.
Our team can help with product questions, sizing guidance, and next steps.