Need an installer?We made it easy for you.
Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.

1 / 7
APOLLO MAX Series — Premium
Heating Capacity: Up to 3,000 ft²
Premium cold-climate hydronics with leaving water up to 170°F for baseboards, radiators, and demanding loops.
Shipping$1,473Free
Need help choosing?










Installed in real homes and workshops
The Apollo heat pump system is very efficient, quiet, and easy to install. It stands out for its clear design, well-organized components, and advanced features like a touchscreen and remote monitoring through an app. It also allows precise temperature control and includes an electric backup for very cold conditions. Overall, it's a reliable and practical system.
Maximizing Efficiency with Apollo Heat Pump
Economical performance that isn't affected by low temperatures.
High-performance air-to-water heat pump designed for residential applications, delivering high-temperature output, all-in-one functionality, and ultra-efficient operation in a compact and quiet system.
| Ambient operating range | -31°F to 110°F |
|---|---|
| Power supply | 220–240V / 1 / 60Hz |
| Water flow / connection | 13 GPM / 1 in |
| Refrigerant charge | See technical manual |
| Dimensions / weight | 50.5 × 20.3 × 43.9 in / 245 lb |
| Heating at 41°F | 41.6 KBTU; 8.8 kW; COP 4.8 |
| Heating at 10°F | 33.6 KBTU; 9.5 kW; COP 3.5 |
| Cooling at 95°F | 12.4–48 KBTU; 3.9 kW; COP 3.8 |
Answers
The APOLLO MAX 4 ton heat pump is a 48,000 BTU cold-climate system. Choose the right capacity by matching the heat pump's output to the building's calculated heating and cooling loads. It can supply water temperatures up to 170°F when required, but using the lowest practical water temperature reduces electricity consumption.
The general planning range for this 4 ton heat pump is up to 3,000 ft². This is a starting point, not a substitute for load calculations. Climate, insulation, windows, ceiling height, air leakage, required water temperature, and indoor distribution all affect the capacity a building needs.
The APOLLO MAX 4 ton is the mid-capacity option, with a general planning range up to about 3,000 ft². Choose it when the calculated load exceeds the 3 ton MAX condition-specific output but does not require the 5 ton or staged capacity.
Compare the building's heating and cooling needs with the 4 ton heat pump output under local winter and summer conditions. Also consider the required system water temperature, indoor equipment, domestic hot water or pool heating, and whether backup heat or additional heat pumps may be needed.
Yes. The APOLLO can supply heated water to radiant floors, fan coils, or compatible air handlers. For cooling, it supplies chilled water to fan coils or air handlers designed for cooling and dehumidification. Radiant-floor cooling requires dew-point and condensation controls and should only be used in a properly engineered system.
The APOLLO MAX operating range extends from -31°F to 110°F and supports cold-climate hydronic heating. Operating range does not mean full output at every temperature, so compare condition-specific capacity and efficiency with the building load to determine whether backup or staged capacity is needed. Detailed MAX performance ratings are published in the technical manual.
Yes. APOLLO MAX supports radiant floors and other low-temperature hydronic emitters, where lower supply-water temperatures generally improve heat-pump efficiency. It can also deliver leaving-water temperatures up to 170°F for compatible systems when required. Confirm the design temperature, emitter output, and building load before replacing a boiler.
Yes, when paired with the correct indirect domestic-hot-water tank, pool heat exchanger, piping, and controls. The outdoor heat pump does not provide tankless domestic hot water by itself. Tank recovery, system priority, pool load, and simultaneous space-heating demands must be included in the system design.
A complete system may include the outdoor heat pump, Hydro Station, household hot-water tank, buffer tank, water pumps, controls, expansion tank, components that remove air and debris from the water loop, electrical protection, and indoor heating or cooling equipment. Exact parts depend on the installation.
APOLLO MAX is designed to reduce annual electricity consumption by approximately 10% compared with comparable R32 systems. Actual savings depend on climate, building load, supply-water temperature, flow, controls, and overall system design. Operating at the lowest practical supply-water temperature helps maximize efficiency.
The product price shown on this page covers the selected equipment configuration, not necessarily a complete installed hydronic system. Total project cost depends on tanks, controls, indoor distribution, electrical work, piping, labor, and project complexity. A system plan is needed for a meaningful installed-cost estimate.
This model uses 220–240V / 1 / 60Hz power and has a published sound level of 44 dB(A). Its rated water flow is 13 GPM through a 1 in water connection. Electrical protection, piping, clearances, freeze protection, startup, and local-code requirements must be confirmed from the current installation manual by qualified professionals.
Verified Google reviews from MBTEK customers across our heating and hydronic product lines.
Loading reviews…
Need an installer?We made it easy for you.
Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.
Any questions?Reach out to us.
Our team can help with product questions, sizing guidance, and next steps.