Need an installer?We made it easy for you.
Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.

1 / 11
Boiler Station — All-in-One
Integrated pumping, backup heat, domestic-hot-water exchange, expansion, and zoning support for a hydronic boiler.
Shipping$908Free
Need help choosing?
The APOLLO Hydro Smart Boiler Station simplifies the installation of a hydronic boiler by bringing many of the components normally installed separately in the mechanical room into one integrated system.
Instead of designing the installation around multiple individual pumps, an expansion tank, backup heater, pressure-management components, controls, valves, and domestic hot water heat-exchange components, the Hydro Smart Boiler Station provides a centralized connection point between the boiler and the rest of the hydronic system.
Connect your boiler to the station, then distribute heat to equipment such as radiant floors, fan coils, air handlers, buffer tanks, domestic hot water tanks, and other hydronic loads.
A complete hydronic boiler system requires much more than the boiler itself. Water or glycol must circulate through the system, pressure must be maintained, different hydronic loads have to be supplied, and backup heat may be required when the boiler is not firing or when additional heating capacity is needed.
The Hydro Smart Boiler Station brings many of these functions together into one organized mechanical-room package.
The Hydro Smart Boiler Station sits between the boiler and the equipment that uses the hot water, helping organize the indoor hydronic side of the system around one central connection point.
Depending on the system design, it can help integrate:
This makes it possible to build a complete heating and hot water system around one centralized hydronic platform instead of assembling many of the core mechanical-room components individually.
The Hydro Smart Boiler Station integrates many of the components normally required around a hydronic boiler installation, including a high-efficiency primary circulator, dedicated stainless DHW circulator, expansion tank, automatic pressurization system, electric backup heater, brazed-plate DHW heat exchanger, purge and fill assembly, isolation valves, system monitoring, and touchscreen controls.
Connections are provided for the boiler, primary hydronic load, domestic hot water circuit, and additional loads such as an air handler or pool heat exchanger, depending on the system design.
The main advantage of the Hydro Smart Boiler Station is not simply that it contains pumps, valves, and controls. It is that these components have already been brought together as part of the APOLLO hydronic system.
That means fewer individual components for the installer to source and assemble, fewer separate pieces of equipment spread throughout the mechanical room, and a hydronic system that is easier to organize, commission, and service.
For homeowners and building owners, that can mean a cleaner and more organized installation.
For contractors, it can mean less field assembly and fewer installation hours, helping reduce the labor and complexity associated with building a complete hydronic boiler system.
Rather than treating circulation, backup heating, domestic hot water heat exchange, expansion, pressure management, and system controls as separate parts of the installation, the Hydro Smart Boiler Station brings these functions together into a single integrated platform.
The result is a hydronic boiler system that is simpler to install, easier to organize, and designed to connect a boiler with the heating and domestic hot water equipment throughout the building.
| Power supply | 220 VAC, 1 phase, 60 Hz |
|---|---|
| Maximum input power | 17 kW |
| Rated / maximum current | 73 A |
| Breaker size | 80 A |
| Backup heater | 15 kW |
| Maximum working pressure | 150 psi (10.3 bar) |
| Operating temperature | 20°F to 200°F (−6.7°C to 93.3°C) |
| System fluid | Water or inhibited propylene glycol |
| Standard glycol concentration | 35% |
| Expansion tank | 9.5 gal (36 L) |
| Heat exchanger | Brazed plate, 18.7 ft² (1.74 m²) |
| Net weight | 293 lb (133 kg) |
| Cabinet size (W × D × H) | 47½ × 16 × 55 in |
| Overall size, with mounting flanges (W × D × H) | 49½ × 16 × 59 in |
| Installation | Indoor only |
| Warranty | 5 years, all components |
Need an installer?We made it easy for you.
Listed installers are independent contractors, not MBTEK employees. They're skilled professionals familiar with our products and capable of efficient installation.
Any questions?Reach out to us.
Our team can help with product questions, sizing guidance, and next steps.